Download Agilent 16517A, 16518A Synchronous State Logic Analyzer PDF

Read or Download Agilent 16517A, 16518A Synchronous State Logic Analyzer (service) PDF

Similar logic books

Logic: An Introductory Course

A whole advent to common sense for first-year collage scholars with out history in common sense, philosophy or arithmetic. In simply understood steps it indicates the mechanics of the formal research of arguments.

If A, Then B

Whereas logical ideas appear undying, placeless, and everlasting, their discovery is a narrative of private injuries, political tragedies, and vast social swap. If A, Then B starts with logic’s emergence twenty-three centuries in the past and tracks its enlargement as a self-discipline ever given that. It explores the place our feel of good judgment comes from and what it truly is a feeling of.

Epistemic Logic and the Theory of Games and Decisions

The convergence of online game conception and epistemic good judgment has been in growth for 2 many years and this booklet explores this extra through collecting experts from diverse specialist groups, i. e. , economics, arithmetic, philosophy, and desktop technological know-how. This quantity considers the problems of data, trust and strategic interplay, with every one contribution comparing the foundational concerns.

Extra info for Agilent 16517A, 16518A Synchronous State Logic Analyzer (service)

Example text

On the 16517A module, touch Stop to stop the acquisition. On the oscilloscope, press the AUTOSCALE key. Read the threshold and voltage swing values. Record the values in the performance test record. a Press the OFFSET key and read the offset voltage. Record the offset voltage value in the threshold field in the performance test record. b Press the More key on the bottom row of menu keys. Press the Measure key. Ensure Measure Chan 1 appears at the top of the vertical row of keys. If Measure Chan 1 does not appear, press the key until it does appear.

3–15 Testing Performance To test the minimum input voltage swing To test the minimum input voltage swing The minimum input voltage swing is the smallest voltage amplitude a data signal can have in which the data signal is still recognizable by the logic analyzer. Using a pulse generator, the minimum voltage swing is characterized. Because the actual threshold voltage of a logic analyzer pod can be some value within the threshold specifications, the threshold voltage is characterized as well. Testing the minimum input voltage swing verifies the performance of the following specification: • 500 mV peak-to-peak These instructions include detailed steps for testing the minimum input voltage swing of the master card pod 1.

Select Trigger Position Center. In the Trigger Position pop-up menu, select Start. Select Done to exit the Acq Control menu. c Select the sec/Div field. 0 ns, then select Done. d Select the Markers Off field, then select Pattern. e Select the Specify Patterns field. Select X entering 1 and O entering 1. Select Done to exit the Specify Patterns menu. f Select the X-pat field. Type "1," then select Done. g Select the O-pat field. Type "1900," then select Done. h Select the O-pat from trigger field, then select from X-marker.

Download PDF sample

Rated 4.58 of 5 – based on 22 votes